Skip Navigation Links
 Home 
 Registration 
 Pre Registered 
  
 Personal page 
 Archive 
Scroll up
Scroll down
-
-
Scroll up
Scroll down
               
Skip Navigation Links
        صفحه اصلی
        ساختار همایش
        مکان برگزاری
        ثبت نام
        ثبت نام شدگان
         مقالات
        مقالات پذیرفته شده
        برنامه همایش
        تماس با ما
        صفحه شخصی
        جستجوی سخنران
        آرشیو سمينار سالهای گذشته
 
مقاله Abstract


Title: Comparison of Anterior Segment Optical Coherence Tomography Parameters in Phacomorphic Angle Closure and Acute Angle Closure Eyes
Author(s): Sasan Moghimi, Farshid Ramezani, Shan Lin
Presentation Type: Oral
Subject: Glaucoma
Others:
Presenting Author:
Name: Sasan Moghimi
Affiliation :(optional) Farabi eye Hospital
E mail: sasanimii@yahoo.com
Phone: 22410361
Mobile: 09126029914
Purpose:

To compare anterior segment optical coherence tomography(AS-OCT) parameters in phacomorphic angle closure and acute primary angle closure(APAC) eyes.

Methods:

In this cross-sectional case series a total of 134 patients with phacomorphic angle closure(28 eyes) or APAC(54 eyes) as well as normal controls (52 eyes) were enrolled. Patients underwent AS-OCT imaging and A-scan biometry of both eyes. Anterior chamber depth(ACD), anterior chamber area(ACA), iris thickness(IT), iris curvature, lens vault(LV), anterior vault(AV) and angle parameters including angle opening distance (AOD 500,AOD750), and trabecular iris space area (TISA500,TISA750) were measured in qualified images using the Zhongshan Angle Assessment Program, and compared among eyes with phacomorphic angle closure, APAC, and normal controls.

Results:

Phacomorphic angle closure and APAC eyes had smaller AOD,ACD,ACA,ACW,AV, and posterior corneal arc length and greater LV than normal controls (p<0.001 for all comparisons). After adjustment for age, sex and pupil diameter, phacomorphic angle closure had greater AOD500(p=0.02), TISA500(p=0.003), TISA750(p=0.05), axial length(p=0.03), and LV(p=0.001); and less ACD(p=0.001), ACA(p=0.003), IT750(p=0.01), and IT2000(p=0.04) than APAC eyes ACD<1.59mm(ORs:29.57,p<0.01) and LV>1042µm(ORs:12.12,p<0.01) were the two biometric parameters that could highly discriminate phacomorphic angle closure from the APAC eyes. In multivariate analysis ACD, LV, AOD500, and AL could significantly distinguish the two entities.

Conclusion:

Ocular biometric parameters can differentiate phacomorphic angle closure from APAC eyes. Shallower ACD and greater lens vault, axial length and anterior chamber angle are the main parameters that distinguish phacomorphic angle closure from APAC.

Attachment:





Last News

  -